PAPR Index

RPB

Current Checked on 2026-07-06

PX5 PAPR

RPB's (GVS-RPB) modular powered air-purifying respirator: a belt- or backpack-mounted blower/filter unit (PX5) that is NOT itself the headtop.

  • USNIOSH 42 CFR 84 · Powered Air-Purifying Respirator (PAPR) Fan Unit
  • UK/EUEN 12941:2023 · TH3/2 (with Z-Link) / TH3 (T-Link, T200, T300 Sterile) / TH2 (Z4) — see generationNote
  • AU/NZAS/NZS 1716:2012 · BMP# 714303

Summary

RPB's (GVS-RPB) modular powered air-purifying respirator: a belt- or backpack-mounted blower/filter unit (PX5) that is NOT itself the headtop. The PX5 draws ambient air through a snap-in filter cartridge (HE / OV-AG-HE / Multi-Gas) fitted directly into the PX5 housing, then pushes filtered air up a separate breathing tube into whichever approved loose-fitting headtop the wearer has selected (Z-Link, Z-Link+, Z-Link Radiant Heat, Z4, Z3, T-Link, T200, T300 Sterile, Nova 3). Approved by NIOSH (US) and certified to EN 12941 (UK/EU) and AS/NZS 1716:2012 (AU/NZ).

Specification

Maker
RPB
System
PX5 PAPR
Status
Current
US approval
NIOSH 42 CFR 84
Powered Air-Purifying Respirator (PAPR) Fan Unit
UK/EU approval
EN 12941:2023
TH3/2 (with Z-Link) / TH3 (T-Link, T200, T300 Sterile) / TH2 (Z4) — see generationNote
AU/NZ approval
AS/NZS 1716:2012
BMP# 714303
Record status
✓ Verified · 2026-07-06

Compatible headtops

9 listed
  • 01Z-Link (NIOSH + CE/AS-NZS)
  • 02Z-Link+ (marketed PX5-only; not broken out as a separate row in the CE apparatus-classification table)
  • 03Z-Link Radiant Heat (aluminized shoulder cape variant)
  • 04Z4 (NIOSH + CE/AS-NZS)
  • 05Z3 (NIOSH markets only)
  • 06T-Link (NIOSH + CE/AS-NZS)
  • 07T200 (NIOSH + CE/AS-NZS)
  • 08T300 Sterile (added in later CE instruction-manual revisions)
  • 09Nova 3 (NIOSH markets only)

Generation, region and notes

Architecture: the PX5 is one of three "required components" of a complete approved system — (1) PX5 blower/filter unit, (2) breathing tube assembly, (3) approved respirator headtop (RPB CE instruction manual Form 7.20.569 Rev 5, p.9, "Make sure you have a complete system"). The filter cartridge (HE 03-892/03-892-P, OV/AG/HE 03-893/03-893-A2, or Multi-Gas 03-894/03-894-ABE/03-895-ABEK) snaps into the PX5 housing itself, not into the headtop — the headtop only carries the visor/cape/face-seal and the far end of the breathing tube. Two breathing-tube part numbers exist because the coupler differs: 04-831 fits Z-Link, Z4, Nova 3 and T-Link; 04-832 is Z3-specific (PX5 Technical Data Sheet Form 7.20.452 R10, p.3). Regional split: NIOSH-market headtops (Z3, Nova 3) are NOT sold/approved in CE & AS/NZS markets — the Nov-2022 PX5 Technical Data Sheet (Form 7.20.452 R10, p.1) explicitly separates "Compatible with NIOSH Markets: Nova 3, T200, T-Link, Z-Link, Z3, Z4" from "CE & AS/NZS Markets: T200, T-Link, Z-Link, Z4" — Z3 and Nova 3 have no CE/AS-NZS filter or breathing-tube SKU equivalent. The CE instruction manual's own "Apparatus Classification and Protection Factor" table (Form 7.20.569 Rev 5, p.6, Table 1.1) lists five CE/AS-NZS headtop rows (Z-Link, T-Link, Z4, T200, T300 Sterile) each with its own EN 12941 class and nominal protection factor: Z-Link = TH3/2 (APF 500/50), T-Link = TH3 (APF 500), Z4 = TH2 (APF 50), T200 = TH3 (APF 500), T300 Sterile = TH3 (APF 500, all combination filters except 03-896-ABEKHg). Z-Link+ is marketed as PX5-compatible on the current product page but does not appear as its own row in that table — likely grouped under the Z-Link classification, but this is not confirmed by a primary source and should not be assumed without checking the Z-Link+ headtop's own instruction manual. Known cross-document inconsistency (RPB's own documents disagree, flagging per the ESAB precedent): the Nov-2022 PX5 Technical Data Sheet (Form 7.20.452 R10) prints the certification block as "EN12941:1998 +A2:2008 TH3/2 P R SL". The June-2025 PAPR Filters Technical Data Sheet (Form 7.20.621 R2) and the current (©2025) CE instruction manual (Form 7.20.569 Rev 5, cover page and p.5 "Equipment Marking") both cite "EN12941:2023 TH3" instead — a newer edition of the standard. Treat the 2025 documents as current; the 2022 datasheet's standard-edition reference is stale (RPB has not reissued that data sheet since).

Do not confuse the PX5 with RPB's HX5 PAPR (same filter part numbers for HE, but the HX5 is NOT compatible with the OV/Gas cartridges — see the "PAPR filters" datasheet's Compatible-with table, "*The HX5 is not compatible with OV and Gas Filters"). No HX5 records created in this pass — out of scope for this assignment.

Sources

6 documents
www.gvs-rpb.com/assets/resources/RPB-PX5-PAPR-Technical-Data-Sheet-EN-R10.pdf 2026-07-06Manufacturer manual · checked on
What was checked

Official PX5 Technical Data Sheet, Form # 7.20.452 R10, Nov 2022. Confirms package part numbers 03-801/03-801-FR/03-802/03-802-FR, NIOSH-vs-CE/AS-NZS headtop market split, full accessories/consumables part-number table (03-890/03-891/03-892/03-893/03-894/03-892-P/ 03-893-A2/03-894-ABE/03-895-ABEK, 03-855/03-856/03-851/03-852, 07-765 belt family, 03-819 flow meter, 03-822 backpack family, 04-831/04-832 breathing tubes), certification block "EN12941:1998 +A2:2008 TH3/2 P R SL", "NIOSH APPROVED", "AS/NZS 1716:2012 BMP# 714303". Archived in repo: sources/rpb-px5-technical-data-sheet-r10-nov2022.pdf.

www.gvs-rpb.com/assets/resources/GVS-RPB-Technical-Data-Sheet_PAPR-Filters_R2.pdf 2026-07-06Manufacturer manual · checked on
What was checked

Official "PAPR filters" Technical Data Sheet, Form # 7.20.621 R2, June 2025. Certification block updated to "EN12941:2023 TH3". Confirms full CE/AS-NZS filter range including 03-896-ABEKHg (Multi-Gas/Mercury, not covered by a part record yet) and the NIOSH-vs-CE part-number pairing. Archived in repo: sources/rpb-papr-filters-technical-data-sheet-r2-jun2025.pdf.

www.gvs-rpb.com/assets/resources/GVS-RPB-Catalog-E6-PX5-PAPR.pdf 2026-07-06Manufacturer manual · checked on
What was checked

GVS-RPB North American Catalog 2022, "PX5 PAPR" section (pp.91-101). Confirms starter-pack contents/part numbers (03-801/802/803 and FR variants), headtop-approval part numbers by headtop family (Z-Link/Z4/T-Link/T200), and a "PX5 PAPR Parts" exploded list (03-810 fan housing, 03-811 belt support mount, 03-812 door cover, 03-813 HEPA(P3) filter door, 03-814 gas filter door, 03-815 battery door assembly incl. 03-818 hinge, 03-817 battery door seal, 03-819 flow meter, 04-831/04-841 breathing tubes, 09-021 power cable). Archived in repo: sources/rpb-gvs-rpb-na-catalog-2022-px5-section.pdf.

www.gvs-rpb.com/assets/resources/GVS-RPB-PX5_PAPR_CE_UI_R5.pdf 2026-07-06Manufacturer manual · checked on
What was checked

Official PX5 CE instruction manual, Form # 7.20.569 Rev 5 (©2025 GVS-RPB Safety LLC). Cover certification "EN 12941:2023 TH3"; p.6 Table 1.1 "Apparatus Classification and Protection Factor" gives the per-headtop EN 12941 class/APF table cited in generationNote; p.9 "Make sure you have a complete system" describes the 3-component architecture; pp.31-33 give PX5 cleaning/storage and 03-855/03-856 battery specification tables (run times, charge/storage temps, 300+/500+ cycle counts); p.31 names the Belt Support (03-811). Archived in repo: sources/rpb-px5-ce-ui-instruction-manual-r5.pdf.

www.gvs-rpb.com/assets/resources/RPB-PX5-PAPR-NIOSH-Instruction-Manual-EN-R3.pdf 2026-07-06Manufacturer manual · checked on
What was checked

Official PX5 NIOSH instruction manual, Form # 7.20.569 Rev 3 (per footer "PX5 PAPR UI R3"). p.4 "Protection Provided and Limitations": "The RPB PX5 is approved by NIOSH... It is approved to be used with the 03-892 High Efficiency (HE) Filter, the 03-893 Organic Vapor/Acid Gas/High Efficiency (OV/AG/HE) Cartridge, and the 03-894 Multi-Gas Cartridge." p.7 confirms the 3-component "complete NIOSH approved respirator system" (Respirator Head-top Assembly + Breathing Tube Assembly + PX5 PAPR). Archived in repo: sources/rpb-px5-niosh-instruction-manual-r3.pdf.

www.gvs-rpb.com/papr/px5 2026-07-06Manufacturer page · checked on
What was checked

Current official PX5 product page. Lists compatible headtops as "Z-Link, Z-Link+, Z-Link Radiant Heat, Z4, T-Link, T200" — notably omitting Z3 and Nova 3, which the 2022 NIOSH-market datasheet lists as compatible. Possible page-content drift or those headtops being deprioritised on the current NA marketing site; the underlying NIOSH approval documents were not re-checked for a Z3/Nova 3 discontinuation notice. Also the only source found for "Z-Link+" as PX5-compatible by name.

Spares that fit

13 parts recorded for this system

Parts whose fitment record names this system. “Fit evidence” is the tier of the fitment claim and its source. Market price bands are observed market ranges, not quotes, and are not our shop prices.

Spares that fit RPB PX5 PAPR
Part numberPartCategoryFit evidenceRegionsOur shopMarket price band
03-855PX5 Standard BatteryBatteryManufacturer listedsource, checked 2026-07-06US, UK, EU, AU/NZ––
03-856PX5 High Capacity BatteryBatteryManufacturer listedsource, checked 2026-07-06US, UK, EU, AU/NZ––
03-851PX5 Battery ChargerChargerManufacturer listedsource, checked 2026-07-06US, UK, EU, AU/NZ––
03-892HE Filter - HEPA Particulate (NIOSH)FilterOfficially approvedsource, checked 2026-07-06US––
03-892-PHE (P) Filter - HEPA Particulate (CE & AS/NZS)FilterOfficially approvedsource, checked 2026-07-06UK, EU, AU/NZ––
03-890Pre-filter (10 Pack)Pre-filterManufacturer listedsource, checked 2026-07-06US, UK, EU, AU/NZ––
03-893OV/AG/HE Cartridge (NIOSH)Gas cartridgeOfficially approvedsource, checked 2026-07-06US––
03-893-A2OV/HE (A2P) Combination Filter (CE & AS/NZS)Gas cartridgeOfficially approvedsource, checked 2026-07-06UK, EU, AU/NZ––
03-894Multi-Gas Cartridge (NIOSH)Gas cartridgeOfficially approvedsource, checked 2026-07-06US––
03-891PAPR Spark ArrestorSpark arrestorManufacturer listedsource, checked 2026-07-06US, UK, EU, AU/NZ––
04-831PAPR Breathing Tube (for Z-Link, Z4, Nova 3 and T-Link)HoseOfficially approvedsource, checked 2026-07-06US, UK, EU, AU/NZ––
04-832PAPR Breathing Tube (for Z3)HoseManufacturer listedsource, checked 2026-07-06US––
07-765PX5 Belt (standard, 2 inch)BeltManufacturer listedsource, checked 2026-07-06US, UK, EU, AU/NZ––

Compare with

Other systems, same measures

The three systems that share the most approval regions with this one (US, UK/EU, AU/NZ).

3M Speedglas Adflo PAPR
Status
Current
EN class
TH2 / TH3
NIOSH
Yes
Headtops
6
Checked
✓ 2026-07-04
Compare side by side
Jackson Safety Airmax Elite PAPR (model R60)
Status
Current
EN class
TH3 P R SL
NIOSH
Yes
Headtops
2
Checked
✓ 2026-07-06
Compare side by side
Kemppi PFU 210e Powered Filter Unit
Status
Current
EN class
TH2 / TH3
NIOSH
No
Headtops
3
Checked
✓ 2026-07-06