RPB
Current Checked on 2026-07-06PX5 PAPR
RPB's (GVS-RPB) modular powered air-purifying respirator: a belt- or backpack-mounted blower/filter unit (PX5) that is NOT itself the headtop.
- USNIOSH 42 CFR 84 · Powered Air-Purifying Respirator (PAPR) Fan Unit
- UK/EUEN 12941:2023 · TH3/2 (with Z-Link) / TH3 (T-Link, T200, T300 Sterile) / TH2 (Z4) — see generationNote
- AU/NZAS/NZS 1716:2012 · BMP# 714303
Summary
RPB's (GVS-RPB) modular powered air-purifying respirator: a belt- or backpack-mounted blower/filter unit (PX5) that is NOT itself the headtop. The PX5 draws ambient air through a snap-in filter cartridge (HE / OV-AG-HE / Multi-Gas) fitted directly into the PX5 housing, then pushes filtered air up a separate breathing tube into whichever approved loose-fitting headtop the wearer has selected (Z-Link, Z-Link+, Z-Link Radiant Heat, Z4, Z3, T-Link, T200, T300 Sterile, Nova 3). Approved by NIOSH (US) and certified to EN 12941 (UK/EU) and AS/NZS 1716:2012 (AU/NZ).
Specification
- Maker
- RPB
- System
- PX5 PAPR
- Status
- Current
- US approval
- NIOSH 42 CFR 84
Powered Air-Purifying Respirator (PAPR) Fan Unit - UK/EU approval
- EN 12941:2023
TH3/2 (with Z-Link) / TH3 (T-Link, T200, T300 Sterile) / TH2 (Z4) — see generationNote - AU/NZ approval
- AS/NZS 1716:2012
BMP# 714303 - Record status
- ✓ Verified · 2026-07-06
Compatible headtops
9 listed- 01Z-Link (NIOSH + CE/AS-NZS)
- 02Z-Link+ (marketed PX5-only; not broken out as a separate row in the CE apparatus-classification table)
- 03Z-Link Radiant Heat (aluminized shoulder cape variant)
- 04Z4 (NIOSH + CE/AS-NZS)
- 05Z3 (NIOSH markets only)
- 06T-Link (NIOSH + CE/AS-NZS)
- 07T200 (NIOSH + CE/AS-NZS)
- 08T300 Sterile (added in later CE instruction-manual revisions)
- 09Nova 3 (NIOSH markets only)
Generation, region and notes
Architecture: the PX5 is one of three "required components" of a complete approved system — (1) PX5 blower/filter unit, (2) breathing tube assembly, (3) approved respirator headtop (RPB CE instruction manual Form 7.20.569 Rev 5, p.9, "Make sure you have a complete system"). The filter cartridge (HE 03-892/03-892-P, OV/AG/HE 03-893/03-893-A2, or Multi-Gas 03-894/03-894-ABE/03-895-ABEK) snaps into the PX5 housing itself, not into the headtop — the headtop only carries the visor/cape/face-seal and the far end of the breathing tube. Two breathing-tube part numbers exist because the coupler differs: 04-831 fits Z-Link, Z4, Nova 3 and T-Link; 04-832 is Z3-specific (PX5 Technical Data Sheet Form 7.20.452 R10, p.3). Regional split: NIOSH-market headtops (Z3, Nova 3) are NOT sold/approved in CE & AS/NZS markets — the Nov-2022 PX5 Technical Data Sheet (Form 7.20.452 R10, p.1) explicitly separates "Compatible with NIOSH Markets: Nova 3, T200, T-Link, Z-Link, Z3, Z4" from "CE & AS/NZS Markets: T200, T-Link, Z-Link, Z4" — Z3 and Nova 3 have no CE/AS-NZS filter or breathing-tube SKU equivalent. The CE instruction manual's own "Apparatus Classification and Protection Factor" table (Form 7.20.569 Rev 5, p.6, Table 1.1) lists five CE/AS-NZS headtop rows (Z-Link, T-Link, Z4, T200, T300 Sterile) each with its own EN 12941 class and nominal protection factor: Z-Link = TH3/2 (APF 500/50), T-Link = TH3 (APF 500), Z4 = TH2 (APF 50), T200 = TH3 (APF 500), T300 Sterile = TH3 (APF 500, all combination filters except 03-896-ABEKHg). Z-Link+ is marketed as PX5-compatible on the current product page but does not appear as its own row in that table — likely grouped under the Z-Link classification, but this is not confirmed by a primary source and should not be assumed without checking the Z-Link+ headtop's own instruction manual. Known cross-document inconsistency (RPB's own documents disagree, flagging per the ESAB precedent): the Nov-2022 PX5 Technical Data Sheet (Form 7.20.452 R10) prints the certification block as "EN12941:1998 +A2:2008 TH3/2 P R SL". The June-2025 PAPR Filters Technical Data Sheet (Form 7.20.621 R2) and the current (©2025) CE instruction manual (Form 7.20.569 Rev 5, cover page and p.5 "Equipment Marking") both cite "EN12941:2023 TH3" instead — a newer edition of the standard. Treat the 2025 documents as current; the 2022 datasheet's standard-edition reference is stale (RPB has not reissued that data sheet since).
Do not confuse the PX5 with RPB's HX5 PAPR (same filter part numbers for HE, but the HX5 is NOT compatible with the OV/Gas cartridges — see the "PAPR filters" datasheet's Compatible-with table, "*The HX5 is not compatible with OV and Gas Filters"). No HX5 records created in this pass — out of scope for this assignment.
Sources
6 documentsSpares that fit
13 parts recorded for this system
Parts whose fitment record names this system. “Fit evidence” is the tier of the fitment claim and its source. Market price bands are observed market ranges, not quotes, and are not our shop prices.
| Part number | Part | Category | Fit evidence | Regions | Our shop | Market price band |
|---|---|---|---|---|---|---|
| 03-855 | PX5 Standard Battery | Battery | Manufacturer listedsource, checked 2026-07-06 | US, UK, EU, AU/NZ | – | – |
| 03-856 | PX5 High Capacity Battery | Battery | Manufacturer listedsource, checked 2026-07-06 | US, UK, EU, AU/NZ | – | – |
| 03-851 | PX5 Battery Charger | Charger | Manufacturer listedsource, checked 2026-07-06 | US, UK, EU, AU/NZ | – | – |
| 03-892 | HE Filter - HEPA Particulate (NIOSH) | Filter | Officially approvedsource, checked 2026-07-06 | US | – | – |
| 03-892-P | HE (P) Filter - HEPA Particulate (CE & AS/NZS) | Filter | Officially approvedsource, checked 2026-07-06 | UK, EU, AU/NZ | – | – |
| 03-890 | Pre-filter (10 Pack) | Pre-filter | Manufacturer listedsource, checked 2026-07-06 | US, UK, EU, AU/NZ | – | – |
| 03-893 | OV/AG/HE Cartridge (NIOSH) | Gas cartridge | Officially approvedsource, checked 2026-07-06 | US | – | – |
| 03-893-A2 | OV/HE (A2P) Combination Filter (CE & AS/NZS) | Gas cartridge | Officially approvedsource, checked 2026-07-06 | UK, EU, AU/NZ | – | – |
| 03-894 | Multi-Gas Cartridge (NIOSH) | Gas cartridge | Officially approvedsource, checked 2026-07-06 | US | – | – |
| 03-891 | PAPR Spark Arrestor | Spark arrestor | Manufacturer listedsource, checked 2026-07-06 | US, UK, EU, AU/NZ | – | – |
| 04-831 | PAPR Breathing Tube (for Z-Link, Z4, Nova 3 and T-Link) | Hose | Officially approvedsource, checked 2026-07-06 | US, UK, EU, AU/NZ | – | – |
| 04-832 | PAPR Breathing Tube (for Z3) | Hose | Manufacturer listedsource, checked 2026-07-06 | US | – | – |
| 07-765 | PX5 Belt (standard, 2 inch) | Belt | Manufacturer listedsource, checked 2026-07-06 | US, UK, EU, AU/NZ | – | – |
Compare with
Other systems, same measures
The three systems that share the most approval regions with this one (US, UK/EU, AU/NZ).
- Status
- Current
- EN class
- TH2 / TH3
- NIOSH
- Yes
- Headtops
- 6
- Checked
- ✓ 2026-07-04
- Status
- Current
- EN class
- TH3 P R SL
- NIOSH
- Yes
- Headtops
- 2
- Checked
- ✓ 2026-07-06
- Status
- Current
- EN class
- TH2 / TH3
- NIOSH
- No
- Headtops
- 3
- Checked
- ✓ 2026-07-06